VEZMARA logo

TNA TX7932 Handheld Fire Alarm Device Programmer Read Write and Erase

TNA TX7932 Handheld Fire Alarm Device Programmer Read Write and Erase
Tanda Technology (TNA) logo
ManufacturerTanda Technology (TNA)

TNA TX7932 Handheld Fire Alarm Device Programmer Read Write and Erase

0.0 (0)Rated 0.0 out of 5
SKU: VZ-PPE-ELEC-076
Price on Request

TNA TX7932 Handheld Fire Alarm Device Programmer. Read, write, and erase device parameters (address, sensitivity, mode, type). T&A Protocol. LCD display (16 characters). Powered by 2 x 1.5V AA batteries (included) or micro-USB. Dimensions: 135 x 60 x 30 mm. ABS plastic, grey glossy finish. Auto power-off after 3 minutes. Price mentioned per piece.

Available sizes

Dimensions(L x W x H)135mm x 60mm x 30mm

Available colors

Grey
1
Quality inspected
Fast nationwide delivery
7-day return request (terms apply)

The TX7932 is a compact, rugged handheld programmer designed for use with the TNA / TANDA addressable fire-alarm device family. It allows engineers to read, write and erase device parameters such as addresses, sensitivity levels and operating modes directly onsite. The unit is powered by twin 1.5 V AA batteries, includes a pluggable programming cable with alligator clips for secure terminal connection, and features an LCD display plus function keys for ease of programming. Key Features: Write, read and erase device parameters (address, sensitivity, mode, type) for TNA/TANDA devices; Pluggable programming cable with end alligator clip to ensure tight contact with the device terminal; LCD display (16 characters) and functional keys allow simple single-button activation of common functions; Low current consumption for extended battery life; auto power-off after approx. 3 minutes of inactivity. Circuit protection against accidental clip-reverse or short; Battery powered (2 × 1.5 V AA) and micro-USB supply option; Compact dimensions approx. 135 mm × 60 mm × 30 mm; ABS housing. Industrial Uses / Applications: On-site configuration of addressable fire alarm devices (set/reset device addresses); Programming and adjusting detector sensitivity and operating modes during installation or maintenance; Troubleshooting and testing fire alarm components onsite; Reading stored device parameters for system diagnostics; Use by fire alarm engineers and technicians during commissioning and servicing of addressable systems.

Safety Information

Handheld programmer for fire alarm devices. Use as per manufacturer instructions. Do not reverse polarity on battery or clip connections. Store in a cool, dry place. Remove batteries if not in use for extended periods.

Product Data Sheet

Material
ABS Plastic (Grey Glossy Finish)
Brand
TNA
SKU
VZ-PPE-ELEC-076
Model
TX7932
Type
Handheld Fire Alarm Device Programmer
Battery Requirement
2 × 1.5V AA Batteries (Included)
USB Power Supply
Micro-USB Interface
Current Consumption
Standby: 0μA / In Use: 20mA
Protocol
T&A Protocol
Material / Colour
ABS Plastic / Grey Glossy Finish
Dimensions (L × W × H)
135mm × 60mm × 30mm
Humidity Tolerance
0–95% Relative Humidity, Non-Condensing
Auto Power-Off
After 3 minutes of inactivity
Pricing
Per Piece
Application
On-Site Configuration of Addressable Fire Alarm Devices, Programming Detector Sensitivity, Troubleshooting and Testing, Reading Device Parameters, Commissioning and Servicing

Key Features

  • Handheld Programmer
  • Fire Alarm Device Programmer
  • Read Write Erase
  • T&A Protocol
  • LCD Display
  • 16 Character Display
  • 2 x 1.5V AA Batteries
  • Micro-USB Power Supply
  • 20mA Current Consumption
  • Auto Power-Off
  • 3 Minutes Inactivity
  • Circuit Protection
  • Pluggable Programming Cable
  • Alligator Clips
  • ABS Plastic
  • Grey Glossy Finish
  • 135 x 60 x 30 mm
  • 0-95% RH
  • On-Site Configuration
  • Address Setting
  • Sensitivity Adjustment
  • Troubleshooting
  • Diagnostics
  • Fire Alarm Engineers
  • Technicians
  • Commissioning
  • Servicing
  • Sold Per Piece

Certifications & Compliance

No certifications listed.

0.0
0.0Rated 0.0 out of 5

Based on 0 reviews

Please sign in to leave a review for this product.

Related Products

Hot Aerosol Fire Extinguishing Device Automatic Fire Suppression for Electrical Panels

Hot Aerosol Fire Extinguishing Device Automatic Fire Suppression for Electrical Panels

Hot Aerosol Fire Extinguishing Device. Model: QRR0.01G. Automatic fire suppression for electrical panels. Operating temperature: -50°C to +90°C. Service life: 10 years. Extinguishing density: 100 g/m³. Activation time: ≤15 seconds. Compliant with EN 15276-1:2019 & EN 15276-2:2019. Price mentioned per piece.

0.0 (0)Rated 0.0 out of 5
Rs. 2,850
T1601 Covid Protection Infrared Thermometer

T1601 Covid Protection Infrared Thermometer

T1601 Covid Protection Infrared Thermometer (Model AD801). Non-contact infrared measurement. Measuring distance: 3 cm to 5 cm. Measurement range: 34°C to 42.9°C. Accuracy: ±0.2°C. Instant reading in approx. 1 second. 16 measurement records. Three-color backlight display (Green/Orange/Red). Powered by 2 x AAA batteries. Price mentioned per piece.

0.0 (0)Rated 0.0 out of 5
Rs. 3,000
FLIR K2 Thermal Imaging Camera

FLIR K2 Thermal Imaging Camera

FLIR K2 Thermal Imaging Camera. 160 x 120 IR resolution. 3" LCD display (320 x 240 pixels). Temperature range: -20°C to +150°C and 0°C to +500°C. Thermal sensitivity: <100 mK. IP67 water-resistant, 2m drop-resistant. Rechargeable Li-ion battery (approx. 4 hours). Includes 2 batteries, charger, strap, power supply, USB cable. Price mentioned per piece.

0.0 (0)Rated 0.0 out of 5
Price on Request
BRK Electronics 83RN Smoke Alarm

BRK Electronics 83RN Smoke Alarm

BRK Electronics 83RN Smoke Alarm. Dual-ionization chamber sensor. Power source: AC 220V + 9V battery backup. Alarm sound level: 85 dB at 10 ft. Operating temperature: 4°C to 38°C. Humidity range: 10% to 90% RH. Dimensions: 5.61" dia x 1.63" height. Weight: 6.4 oz (approx. 0.18 kg). UL 217 & NFPA 72 approved. Price mentioned per piece.

0.0 (0)Rated 0.0 out of 5
Rs. 1,800